電廠(chǎng)#3燃機跳機事件分析報告
1、事件經(jīng)過(guò)
2006年5月8日22:46時(shí),#3燃機值班員正在給#3燃機加抑釩劑,突然聽(tīng)到燃機運行聲音下降,馬上檢查重油表、輕油表已停止轉動(dòng),初步判斷#3燃機跳機,立即跑回TCC間,經(jīng)確認#3燃機已跳機,立即匯報值長(cháng),并確認發(fā)電機出口開(kāi)關(guān)已跳開(kāi),截止閥已關(guān)閉,防喘閥已開(kāi),燃機惰走。打印的報警有:
22:46:43:593 liquid fuel forwarding press low trip
22:46:43:593 heavy fuel trip
22:46:44:718 lockout relay 74/86 2a trip
22:46:44:718 g60a gloal alarm
22:46:47:218 gt axtat shaft displacement
22:46:48:000 voter mismatch
22:46:54:593 rfgulalor not in operation
22:47:04:093 turb compl flop damper not closed
22:47:13:593 exhaust frame pressure trouble
22:47:18:468 heavy fuel purge failure to close
22:47時(shí)向值長(cháng)匯報#3燃機輕油泵進(jìn)口壓力低跳機,并詢(xún)問(wèn)#1燃機是否起了輕油泵。初步判斷由于起了輕油泵,泵入口搶油導致#3燃機輕油入口壓力低,開(kāi)關(guān)動(dòng)作。
與此同時(shí),值長(cháng)令#4機快速降負荷,由于汽機HP主汽門(mén)前溫度下降過(guò)快,值長(cháng)令#4機打閘停機。22:48時(shí)值長(cháng)將#3燃機跳機和4#機打閘情況匯報省調。
23:06時(shí)#3燃機投入盤(pán)車(chē),盤(pán)車(chē)轉速正常,有輕微刮缸。
23:10時(shí)#3燃機開(kāi)始沖油,并啟動(dòng)#1燃機輕油泵做試驗,試驗結果證實(shí)#1燃機啟動(dòng)輕油泵會(huì )造成#3燃機輕油泵入口壓力瞬間低至-0.5bar,致使壓力開(kāi)關(guān)動(dòng)作(壓力開(kāi)關(guān)定值-0.2bar)。23:30時(shí)沖油結束。
23:46時(shí)值長(cháng)令#3燃機發(fā)啟動(dòng)令,24:00時(shí)#3燃機并網(wǎng),5月9日6:56時(shí)#4機并網(wǎng)。
2、原因分析
此次故障的原因比較清楚,就是由于#1機做啟機準備時(shí),啟動(dòng)輕油泵,導致泵入口搶油,造成#3燃機輕油入口壓力低,開(kāi)關(guān)動(dòng)作,機組跳機。由于#3機故障跳機,造成#4機被迫停機。
3、暴露問(wèn)題
(1)在故障原因很明確的情況下,應爭取時(shí)間,向調度申請迅速恢復啟機。此次#3燃機從跳機到再次并網(wǎng),共用時(shí)1小時(shí)15分。屬人為原因造成的延誤。
(2)相關(guān)試驗應盡可能安排在機組停機時(shí)試驗,不要在安排啟機的機組上耽誤時(shí)間。
(3)運行人員在此次試驗中做得不徹底,如應檢查一臺機組沖油時(shí),是否會(huì )對另一臺機的泵的出口及切換站的油壓產(chǎn)生影響。
4、防范措施
(1)檢修部要進(jìn)行技改,將泵入口前輕油壓力低跳機邏輯取消。
(2)在技改未完成前,機組啟動(dòng)時(shí),運行人員要將#1、#3機的L63FD2L信號強制為“0”。
(3)燃機在燒重油狀態(tài)下跳機,在機組重新啟動(dòng)沖油前,要將雙聯(lián)濾和高壓油濾切至備用濾,以減小沖油時(shí)間。被置換的雙聯(lián)濾和高壓油濾要盡快將其中的重油置換出來(lái),以免堵塞濾網(wǎng)。
(4)運行部要加強對運行人員的技術(shù)培訓,做好事故預想,將已有的事故預想匯編成冊,下發(fā)給運行人員學(xué)習,不斷提高操作技能。
?